Siemens Skyra 3T MRI Scanner



The patient personalized framework gives us onboard guidance to optimize the time the patient spends in the magnet.
 
Combined with the increased signal to noise ratio of 4G*, the image quality is clear and sharp to the edges of the 50 x 50 x 45 cm field of view.

Ultra high-density coils are combined with the highest channel configurations ever offered.
 
Ultra-lightweight coils combine seamlessly to support large anatomic coverage, for instance combining head, neck, body and spine coil elements to create a neurovascular array.
 
This 3T technology is an exciting new choice for patients at our hospital suites.
 
* Up to 20% increase due to a new RF design with up to 128 RF channels.
 
Ultra-light coils.
Tim DirectConnect™ cableless coils are easier and faster to handle. And they're ultra-lightweight so they're easy on you, too.
 
New Tim Dockable Table accelerates patient set-up.
Fast patient preparation, easy patient transport, comfort for immobile patients, and flexibility in emergency situations.
Holds up to 250 kg / 550 lb to accomodate more patients.

MR Open .5 T by Paramed


Unlike other systems, the MROpen is totally open to the environment–making patient experiences relaxed, cooperative and reassuring. And that contributes to superior image quality and improved productivity.

Comprehensive lumbar spine applications, dynamic imaging, and weight–bearing imaging are now easy to perform, quickly and cost-effectively. The large patient space allows for easy access and positioning. And our user-friendly software includes optimized protocols for each anatomical site, and allows maximum flexibility in customizing clinical protocols. The MROpen has the potential for future advanced applications–where the “sky’s the limit.”


MR Open .5 T by Paramed

  • Revolutionary design
  • Unique superconductor technology
  • Cryogenic-free operation
  • Low power consumption
  • Trouble-free maintenance
  • Ease-of-use



The new technology at the core of the MROpen is based on a leading-edge superconducting material MgB2 (Magnesium Diboride), which allows for low cost, cryogenic-free operation, and low power consumption. There’s no need for helium and it’s associated risks and costs. There’s no cryogenic lines, no compliance with pressure vessel regulations, and no quench risks. It’s as easy to use as a permanent magnet! And that means your staff can virtually turn the system on or off as needed. The MROpen’s 0.5T transverse magnetic field makes it possible to use phased array multichannel coils–combining flat with solenoid type coils—to maximize the signal-to-noise ratio in all anatomical areas.


For more information about MROpen, please continue on to the Features page or request a brochure by calling 1 (847) 470-0649 or emailing info@paramed-usa.com.






Siemens MAGNETOM Verio 3T MRI Scanner

  

The Siemens MAGNETOM Verio 3T provides:

Revolutionary Technology
The MAGNETOM Verio provides diagnostic confidence with a range of clinical applications that can allows physicians to assess treatment earlier than ever before. The 3T Magnet allows applications that were once only possible in the realm of research but can now be translated into daily clinical routine.

Revolutionary Comfort
The MAGNETOM Verio has an extra-large open bore (70 cm) that accommodates a wide range of patients including the obese and elderly. The extra space is also excellent for those who suffer from claustrophobia during an MRI exam.

Revolutionary Speed
The MAGNETOM Verio, with the power of Tim™ (Total imaging matrix) technology, has up to 102 seamlessly integrated matrix coil elements and up to 32 independent radiofrequency channels that allow flexible coil combinations to make patient and coil repositioning virtually unnecessary. Patients can be positioned once for multi-station studies -- a big benefit for frail or elderly patients.

 
Siemens 3T Verio
  • 70 cm bore
  • 173 cm length
  • VQ Gradients - 45 mT/m and slew rate of 200 mT/m/ms
  • Tim 102x32 RF System
  • 550 lbs Patient Table Weight Capacity - with vertical lift
  • Avotec Silent Vision SV-6011 LCD projection system
  • Avotec Silent Scan SS-3100 audio system
  • Current Designs button response units
  • 64-channel MRI-compatible EEG (Brain Vision)

3T RF Coils
  • 32 Channel Dedicated Head Coil
  • 32 Channel cardiac coil
  • 12 Channel Head Matrix Coil
  • 4 Channel Neck Matrix Coil
  • 16 Channel Neurovascular Matrix Coil
  • 24 Channel Spine Matrix Coil
  • 12 Channel Body Matrix Coil (quantity 2)
  • 4 Channel Shoulder Coil
  • 15 Channel Tx/Rx Knee Coil
  • 8 Channel Wrist Coil
  • 8 Channel Foot/Ankle Coil
  • 4 Channel Flex Coil Large
  • 4 Channel Flex Coil Small

3T Application Packages
  • Neuro Suite
  • Angio Suite
  • Cardiac Suite
  • Onco Suite
  • Breast Suite
  • Ortho Suite
  • Pediatric Suite
  • Scientific Suite
  • iPAT and iPAT Extensions - Parallel Imaging in 2 directions simultaneously
  • 2D/3D PACE - navigator based motion correction for cardiac and body imaging
  • SPACE - 3D Turbo Spin Echo - whole-body 3D imaging reduces SAR. T2, T1, PD and dark fluids
  • Advanced Cardiac Imaging Package
  • Flow Quantification Package
  • Argus Flow post-processing software
  • Argus 4D Ventricular Function post-processing software
  • In-Line Ventricular Function post-processing software
  • BLADE - whole-body real-time motion correction - any plane, any contrast
  • Composing - stitching software
  • In-Line Composing - stitching simultaneous to image acquisition
  • In-Line Diffusion - automated processing of ADC-maps, TRACE images
  • Diffusion Tensor Imaging
  • Diffusion Tensor Imaging Evaluation
  • DTI Tractrography
  • In-Line Perfusion - automated processing of GBP, PBP, TTP
  • Tissue 4D - visualize and post-processing of dynamic contrast enhanced data sets for pharmacokinetic modeling
  • Neuro Perfusion Evaluation - post-processing of brain perfusion data sets - relCBV, relCBF, relMTT, PBP, TTP
  • Arterial Spin Labeling - non-contrast neuro perfusion
  • SWI - susceptibility Weighted Imaging
  • In-Line BOLD - real-time calculation & display of statistical (t-value) images during measurement of fMRI paradigms
  • 3D PACE - motion correction for BOLD studies
  • BOLD 3D Evaluation - comprehensive processing and visualization for BOLD fMRI studies
  • fMRI Trigger - optical trigger signal to trigger external stimulation devices for fMRI experiments
  • Single Voxel Spectroscopy - proton spectra from single voxel
  • Spectroscopy Evaluation - post-processing of spectroscopy data sets
  • 2D Chemical Shift - proton 2D chemical shift (multi-voxel)
  • 3D Chemical Shift - proton 3D chemical shift (multi-voxel)
  • Mapit - cartilage mapping
  • Image Fusion - color overlays for cartilage mapping
  • CISS/DESS - high resolution 3D neuro (CISS) and ortho (DESS) sequences
  • Expert-i - remote access via network) to the scanner console for planning and processing support

Open MRI - 1.5 Tesla Siemens Espree


 1.5 Tesla Siemens Espree Open MRI represents a quantum leap in image quality and advanced applications over conventional lowfield and mid-field open MRI. The Espree Open MRI high-field magnet and sophisticated technology gives our specialists clearer images than other MRI units – and that means a more precise diagnosis for you and your doctor. 
High-definition images from the Espree Open MRI allows imaging of human internal organs with exact and non-invasive methods for diagnosis, treatment and follow-up of cancer, cardiovascular disease, neurological 
disorders and musculoskeletal conditions.

The new “wide open” design, which is the largest opening in the MRI industry, coupled with its high-field strength magnet makes our scanner the first 1.5 Tesla Open MRI in Pennsylvania and one of the first worldwide to accommodate patients regardless of height or weight. 

The scanner’s spaciousness and high performance result in faster, more comfortable procedures. This helps reduce anxiety and nearly eliminates that closed-in feeling. In fact, the majority of our MRI exams can now be performed with the patient’s head outside of the scanner.


The Siemens Espree 1.5 T Magnet MRI features a bore opening of nearly 2.3 feet in diameter and almost one foot of free space between a patient's head and the magnet.  The Espree also features the shortest 1.5 Tesla magnet available.  Approximately four feet long, the magnet allows more than 60 percent of exams to be completed with the patient's head outside the bore.

  • Short bore design reduces feelings of claustrophobia
  • Extra wide to accommodate patients up to 500 pounds
  • 1.5 Tesla magnet for superior resolution compared to open MRI
  • Outstanding image accuracy
  • High resolution images in less time
  • 3x more power than conventional open MRI


GE Signa HDx 1.5T MRI Scanner

The GE Signa HDx 1.5T MRI is a whole-body, high resolution, high signal-to-noise ratio scanner with short scan times. The Signa HDx 1.5T MRI is an upgraded modification of the earlier 1.5 Tesla GE systems. The main difference between the HDx 1.5T and the earlier systems is the change to the receive chain architecture that includes 32 independent receive channels and room for 16 additional channel increments. The system features a simplified user interface including a 23-inch LCD display, upgraded image reconstruction architecture called Volume Recon Engine (VRE), and upgraded multi-channel surface coil connectivity.
 
GE Signa HDx 1.5T Features 
  • Quick to learn, Easy to use system controls
  • AutoVoice - preprogram commands in many languages
  • Dockable patient table accommodates patients weighing up to 180kg (400lbs)
  • Low Noise - acoustic management reduces noise within the bore
  • XVRE Volume-Reconstruction Engine for near real time image generation
  • GEM hybrid acceleration technique uses variable sampling to increase image acceleration
  • TRICKS-XV technology offers full 3D volumes in 2.5 seconds with high detail
  • PROPELLER - offers consistent image quality in head studies, pediatric, elderly, or confused patients

GE Signa HDx 1.5T MRI Specifications:

 
SV Magnet
HP 9300 workstation
NEC LCD Widescreen monitor
Leybold cold head
HFD gradient/PDU cabinet
Excite III systems cabinet
Single Sun VRE array processor
Lytron gradient chiller
EPI
FGE
CINE
FSE&FLAIR
TOF
PCVI
RESEARCH
RESEARCH PSD
SPECTRO/PROBE
SGD ECHOSPEED
DW EPI, FLAIR EPI
SPECIAL
SMART PREP
SSFSE
THREE PLANE LOC
MODALITY WORKLIST
E3DTOF
FSE XL
BLOODSUPP
FAST CINE
SGDPERF
IDRIVE
PRO
IDRIVE
SMART PREP 2000 UPGRADE
MULTI NUCLEAR SPECTROSCOPY
FUNCTOOL 2
VOXTOOL
IVI
CLARIVIEW
ULTRASHORT TR
T2 BREATHHOLD
ACGD PLUS
FLUORO TRIGGERED MRA
MRCP3, DYNAMIC R1
FIESTA 2D & 3D
DELAYED ENHANCEMENT
ASSET
DIFFUSION TENSOR
3DFRFSE
ASSET PLUS
TRICKS
FIESTA c
PROPELLER DWI
3D FATSAT FIESTA
BRAINWAVE RT
PROPELLERT2
2D FAT SAT FIESTA
8 CHANNEL SYSTEM
LAVA
FIBER TRAK
FLAIR3D
MULTI PHASE
BLOOD FLOW
VOLUME MEASUREMENTS
TIME COURSE
T2MAP
2D MERGE, BRAVO
COSMIC
HDX KEY
IDEAL
3D DUAL ECHO
ARC, CUBE, T2
Coil Package: 8 Ch HD Knee, 8 Ch Hi Res Brain, 8 Ch Medrad Neuro Vascular, 8 Ch Body coil, 8 Ch CTL, 4 Ch US Shoulder PA, 4 Ch Medrad Breast

MR Inspire XT Orthopaedic MRI



MRInspire Ankle CoilMRInspire is the most versatile Magnetic Resonance scanner in the “Dedicated Orthopaedic” market segment. It blends the operative flexibility of a compact dedicated system with the best technical solutions for guaranteed superior images. Outstanding image quality, while accommodating high patient volume–that’s the MRInspire.

System installation and setup are extremely fast. Because the MRInspire fits in less than 16 square meters, site requirements are minimal. The MRInspire does not require a separate power supply–our proprietary permanent magnet requires low electric consumption (208V AC single phase). And that translates to a significant cost-savings for your practice. What’s more, the turn key operation includes state-of-the-art Open RF Pavillion.


Everything about the MRInspire is designed to revolutionize the status quo, improve workflow productivity and make high quality care easily accessible and affordable. The MRInspire is easy to install, extremely reliable, and can accommodate high patient volume practices.

MRInspire is also revolutionizing the future: the flexible hardware platform is able to handle coils with MAX technology (Multi Array Cross-tuned) with up to 8 receiving channels, ensuring future evolution in coil technology will be integrated seamlessly.

For more information about MRInspire, please continue on to the Features page or request a brochure by calling 1 (847) 470-0649 or emailing info@paramed-usa.com.

Before purchasing an MRI machine


Before purchasing an MRI machine, the following should be considered:
Is there a need for the machine in your setting?
Is there a consumer base that can afford the scans?
Can you afford to purchase an MRI scan machine? ( The accepted minimum is a 1.5Tesla machine)
Do you have space to house an MRI machine?
Are there qualified personnel to operate the machine?
Are there specialists who can interpret the scans and give a report? 

If there is a demand for a machine, and the purchase is justified,etc.
Usually one can recover the cost of a machine in about 3 years time (assuming regular usage).

Technical Improvements of the Hitachi AIRIS Elite MRI Scanner


   

Hardware

  • New magnet with advanced shimming (+/- .4ppm over 20 cm fov)
  • Advanced gradient amplifiers (faster, 21mt/m amplitde 55tm/s slew rate)
  • Four channel dual quad receivers (multiple array)

Coils

  • Shoulder coil ( multiple array, anatomy fitted)
  • Wrist coil (multiple array)
  • Rapid head coil
  • Rapid lower extremity coil

Software


Fast spin echo improvements

  • FSE Flair sequence
  • Choice of echo train factors from 2 to 256
  • Choice of inter-echo spacing
  • Driven Equilibrium
New pulse sequences
  • Single Shot Fast Spin Echo (SSFSE)
  • Echo Planer Imaging (EPI)
  • Diffusion Imaging (DWI)
Tissue suppression sequences
  • FATSEP
  • FATSAT
  • Mag Transfer Imaging (MTC)
Imaging resolution
  • Imaging matrix size from 128 pixels to 1024 pixels

Scientists have found a way to "read" dreams with MRI SCAN


Scientists have found a way to "read" dreams, a study suggests.
Researchers in Japan used MRI scans to reveal the images that people were seeing as they entered into an early stage of sleep.
Writing in the journal Science, they reported that they could do this with 60% accuracy.
The team now wants to see if brain activity can be used to decipher other aspects of dreaming, such as the emotions experienced during sleep.
Professor Yukiyasu Kamitani, from the ATR Computational Neuroscience Laboratories, in Kyoto, said: "I had a strong belief that dream decoding should be possible at least for particular aspects of dreaming... I was not very surprised by the results, but excited."
Brain wave
People have been trying to understand dreams since ancient Egyptian times, but the researchers who have carried out this study have found a more direct way to tap into our nighttime visions.
The team used MRI scans to monitor three people as they slept.
BrainBrain activity correlated with the images that people saw in their dreams
Just as the volunteers started to fall asleep inside the scanners, they were woken up and asked to recount what they had seen.
Each image mentioned, from bronze statues to keys and ice picks, was noted, no matter how surreal.
This was repeated more than 200 times for each participant.
The researchers used the results to build a database, where they grouped together objects into similar visual categories. For example, hotel, house and building were grouped together as "structures".
The scientists then scanned the volunteers again, but this time, while they were awake and looking at images on a computer screen.
With this, they were able to see the specific patterns of brain activity that correlated with the visual imagery.
Dream machines?
During the next round of sleep tests, by monitoring the brain scans the researchers could tell what the volunteers were seeing in their dreams. They were able to assess which broad category the images were in with 60% accuracy.


"We were able to reveal dream content from brain activity during sleep, which was consistent with the subjects' verbal reports," explained Professor Kamitani.
The researchers now want to look at deeper sleep, where the most vivid dreams are thought to occur, as well as see whether brain scans can help them to reveal the emotions, smells, colours and actions that people experience as they sleep.
Dr Mark Stokes, a cognitive neuroscientist from the University of Oxford, said it was an "exciting" piece of research that brought us closer to the concept of dream-reading machines.
"It's obviously a long way off, but there is no reason why not in principle. The difficult thing is to work out the systematic mapping between the brain activity and the phenomena," he explained.
However, he added that a single dream-reading system would not work for everyone.
"All of this would have to be done within individual subjects. So you would never be able build a general classifier that could read anybody's dreams. They will all be idiosyncratic to the individual, so the brain activity will never be general across subjects," he said.
"You would never be able to build something that could read other peoples thoughts without them knowing about it, for example."

Source: http://www.bbc.co.uk/news/science

PHILIPS Achieva 3.0T MRI Scanner


Philips Achieva 3.0T TX MRI System

The Achieva 3.0T Tx by Philips is the first MRI scanner in the industry to project multiple radio frequency (RF) transmit signals to adjust to the patient’s anatomy. This MRI system provides for enhanced image uniformity and consistency. It completes scans 40% faster than conventional MRI systems.

The Achieva 3.0T TX MRI system delivers high quality diagnostic images for even the most demanding high-field application. This system captures the correct information on the first scan in a shorter amount of time. It delivers more convenience to your patient and increases patient throughput. This MRI scanner provides consistent results across a broad range of clinical applications and patient sizes.



MAGNET TYPE

Weight <4600kg
Bore diameter 60 cm
Maximum FOV 50x50x45 cm
Cryogens  Liquid Helium. Zero boil -off system*under regular scanning conditions



Philips Achieva 3.0T TX MultiTransmit Tech Specs (Technical Specifications)


  • Type: 3 Tesla MultiTransmit MR
  • General description: 3.0-tesla MRI with MultiTransmit technology. Unique patient adaptive system tunes RF transmit to each individual. This provides consistent imaging in difficult anatomy and up to 40% faster exams.
  • Special features: MultiTransmit reduces dielectric shading and provides uniform RF excitation. This optimizes image quality and scan speed, especially in 3T expanding application areas such as breast, body, and cardiac imaging. An Ambient Light Ring relaxes patients.
  • Patient comfort features: SoftTone, Airflow, Intercom, Ambient Experience (optional), dual side controls, Ambient light ring
  • Power Consumption: 480 VAC
  • Installed weight: 9400 lbs
  • Minimum room size: 3.6 x 5.4 x 3.0 m
  • Table weight limit: 550 lbs
  • Magnet field strength: 3 Tesla
  • Magnet Type: Superconducting
  • Magnet bore length: 157 cm
  • Gantry diameter: 60 cm flaring out to 110 cm
  • Gradient Strength: 40/120 and 40/100, 80/200 m T/M
  • Gantry Style: Closed bore - short (<1.5 meters)
  • Active shielded gradient system: Yes
  • FOV, minimum: 0.005 min to 50 max cm
  • Clinical applications: SmartExam, SPAIR (uniform fat supression), TRANCE (noncontrast MR angio), k-t BLAST (3D whole heart in a single breath), 2k imaging, SENSE, DWIBS, ASL
  • Coils: Body, Head, Knee, Neck, Pelvic, Shoulder, Spine, Wrist, Breast, Flex Array, Phased Array
  • FDA clearance status: Cleared