Siemens MAGNETOM Verio 3.0T Tech Specs (Technical Specifications)

Verio Gantry
  • Bore diameter/height of patient opening: 70 cm
  • Overall bore length: 173 cm, cover to cover
  • Bore length with minimum opening: 163 cm
  • In-bore patient comfort features: In-bore lighting (3 levels), in-bore ventilation (3 levels), in-bore intercom, look-out mirror, patient supervision monitor

Verio Magnet
  • Configuration: Superconductive, short bore
  • Strength: 3 Tesla
  • Homogeneity, ppm V-RMS: 4.0 (typical 3.6) ppm @ 50 x 50 x 45 cm DSV, 1.6 (typical 1.2) ppm @ 40 DSV, V-RMS (based on 24-plane plot)
  • Dimensions of maximum useful FOV and homogeneity, (x, y, z), cm: 50 x 50 x 45
  • Frequency drift, ppm/day: <0.1 ppm/hr
  • Shielding: Active, EIS (external interference shielding)
  • Main magnet shimming: Active, passive
  • Patient specific shimming: 3 linear channels with 20 coils, 5 nonlinear second-order channels with 32 coils
  • Cryogen refill frequency: Refill typical 10 years; zero He boil-off technology

Planning and Installation
  • Overall gantry dimensions (including covers), W x H x L: 2.15 x 1.63 x 2.22 m
  • Minimum ceiling height: 2.4 m
  • Extent of fringe field (0.5 mT, 5 gauss) in x, y, z directions, m: 4.6 (axial) x 2.5 (radial)
  • Total weight w/cooling, shielding, gradient/body coil: 8,290 kg (18,238 lb)
  • Minimum dimensions of opening required for installation, W x H: 2.4 x 2.20 m
  • Minimum installation area for magnet: 33 m2
  • Minimum total installation area for system: 33 m2
  • Total number of cabinets required: 2

Power Consumption
  • Line Voltage: 380, 400, 420, 440, 460, 480 V
  • KVA: 110
  • Clinical Use: Whole body
  • DICOM (GANTRY)     
  • Modality worklist SCU: Standard
  • MR Image Storage SCU: Standard
  • Query/Retrieve SCU and SCP: Standard
  • Storage commitment SCU: Standard
  • Modality performed procedure step SCU: Standard
  • IHE profiles supported: Standard

Control Console Workflow
  • Standard user interface: syngo, multimodality user interface
  • Operating system: Windows
  • Local hard disk capacity: 145 GB
  • RAM: 2 GB
  • Removable media: CD
  • Image protocol sharing: Phoenix: DICOM image-based method duplicates protocol via drag and drop; MAGNETOM World posts Phoenix images on Web
  • Features designed to enhance workflow: Autoalign, Phoenix, scan assistant, inline technology, syngo, iPAT(GRAPPA), Tim assistant, utilization management reports, structured reporting, others

Acoustic Noise
  • Sound pressure level (SPL) at peak gradient amplitude and slew rate: 115 dB(A)
  • Reduction technology: Antivibration mounting, noise reduction, systems integration, whisper mode, others

Sequence Selection
  • Spin echo (Minimum TR ms)    
  • Minimum TR, 256 matrix, 30 cm FOV, msec: 6.8, 6.2 for 128 matrix

Gradient echo
  • Minimum TR, 256 matrix, 30 cm FOV, msec: 1.5, 1.4 for 128 matrix
  • Minimum possible TE, msec: 0.29 for EPI matrix 64 in readout
  • Fast-spin-echo max train length: 512
  • Echo planar imaging max train length: 256

Verio Scanning Techniques
  • Echo Planar Imaging: Yes, standard
  • Single shot: Standard; SE, FID
  • Multi shot: 2-D/3-D segmented; SE and FID
  • EPI pulse sequences: Standard; single-shot, multi-shot
  • Maximum EPI factor: 256
  • Neurologic imaging: Standard with neuro suite
  • Perfusion: Standardwith neuro suite
  • Diffusion weighted imaging: Standard with neuro suite
  • Diffusion tensor imaging: Up to 256 diffusion directions, up to 16 B-values, 3-D tractography, exponential ADC, texture diffusion
  • Functional MRI: StandardBOLD sequence; optional inline BOLD sequence, 3-D PACE
  • Spectroscopy (nuclei of interest): Optional single voxel spectroscopy, CSI for hydrogen nuclei (STEAM, spin echo techniques)
  • MRA: Standard with angio suite
  • Time of flight: Standard 2-D/3-D TOF, ceMRA
  • Peripheral: Standard ceMRA protocols
  • Bolus tracking: Standard bolus tracking protocols, Care Bolus
  • Interventional MR: Optional
  • Cardiac imaging: Optional flow quantification, Argus flow (mean/max velocity, color-coded velocity), Argus function (peak/mean velocity, total flow); optional ARGUS 4-D ventricular analysis
  • Cine: Standard CINE sequences
  • Coronary artery: Standard 2-D; optional 3-D
  • Ecg gating: Standard wireless, inline ECG
  • Motion compensation: Yes
  • Prospective respiratory gating: Standard 2-D PACE
  • Maximum number of dimensions: Up to 6
  • Additional (Alarms, high/low)     T/R knee coil, T/R wrist coil

Gradient system
  • Standard name: VQ gradient
  • Standard strength, z-axis, mT/m: 45, in x, y, z-axis
  • Standard slew rate, z-axis, T/m/s: 200
  • Cooling type: Water
  • Amplifier max power/axis, kW: 2,000 V; 625 A
  • Amplifier cooling type: Standard cooling, optional chiller

Verio Coils
  • Integrated body: Standard
  • Type: Array, receive only
  • Number of independent channels: 8, 18, 32
  • Parallel imaging compatible: Yes
  • Head: Standard
  • Diameter, cm: 30 (L) x 30 (W) x 33 (H)
  • Number of elements: 30 x 28
  • Number of independent channels: 8, 18, 32
  • Mirrors for patient head: Yes
  • Neck: Standard
  • Coverage (head to foot), cm: 118
  • Number of elements: 30 x 28
  • CTL spine: Standard
  • Number of elements: 30 x 28
  • Cardiac/abdomen: Standard
  • Dimensions, L x W, cm: 32 x 52 x 4 (H)
  • Flexible (Equivalent Endoscope): Yes
  • Number of elements: 30 x 28
  • Breast: Optional
  • Bilateral: Yes
  • Biopsy access: Yes
  • Number of elements: 30 x 28
  • Shoulder: Optional
  • Dimensions, L x W, cm: 32 x 52 x 4 (H)
  • Number of elements: 30 x 28
  • Whole abdomen: Optional with up to 4 body matrix coils combined
  • Number of elements: 30 x 28
  • Extremity: Optional
  • Diameter, cm: 86 x 30
  • Diameter, cm: 27 x 29
  • Length, cm: 40.5
  • Number of elements: 30 x 28
  • Length, cm: 28 (H)
  • Number of elements: 36
  • Number of independent channels: 8, 18, 32
  • Peripheral vascular: Optional
  • Diameter, cm: 30 x 28
  • Length, cm: 86

Patient Table
  • Detachable: Optional removable tabletop and trolley
  • Dimensions, L x W, cm: 238 x 63
  • Horizontal speed, cm/s: 20
  • Elevating: Standard
  • Minimum height, cm: 50
  • Limited mobility: 250 kg (550 lb)
  • Fully mobile: 250 kg (550 lb)

Image processor
  • Clock speed, GHz: 3.06
  • Operating system: 2x AMD Opteron 248 CPU generation
  • Dedicated RAM (Reconstruction): 8 GB

Image Reconstruction
  • Maximum number of 256 x 256 slices per acquisition sequence: 110,000 images at 512 x 512, uncompressed
  • Number of slices per sec (256 matrix): 8,694 recons/sec 256 x 256 25% rec FOV; simultaneous scan and reconstruction =8 data sets
  • Maximum matrix: 1024 x 1024
  • Minimum slice thickness 2-D/3-D, mm: 0.1/0.05
  • Minimum FOV, cm: 0.5
  • Maximum FOV, cm: 50

Quantitative image analysis tools   
  • Perfusion imaging: Standard calculation time-to-peak maps; optional inline perfusion (GBP, PBP, TTP)
  • fMRI: FuncTool standard; standard calculation t-test maps; optional inline bold evaluation (motion correction, t-test, t-value, color overlay)
  • Diffusion imaging: StandardADC map calculation; optional inline diffusion (real-time calculation trace and ADC maps)
  • Body imaging: Standard 1-D, 2-D PACE, dynamic analysis package includes addition, subtraction, division, multiplication, ADC maps, T1, T2, z-score, TTP, standard deviation
  • 3-D image reconstruction: Standard MIP, targeted MIP, MPR (including curved reconstructions), surface shaded display, MinIP; optional image fusion, vessel view, 3-D VRT, fly through

RF system
  • Power output, kW: 33
  • Amplifier type: Compact air cooled
  • Standard number of channels: 8
  • Optional channel configurations: 18, 32
  • Receiver bandwidth, kHz: 1,000 per channel
  • Location of coil connector (plug): Patient table
  • Standard length of coil cables, m: Variable
  • Number of coil connectors (plugs): 10
  • Coil tuning technique: Automatic

Parallel imaging    
  • Name: iPAT
  • Technique: mSENSE and GRAPPA
  • Calibration Technique: Automatic
  • Maximum parallel acquisition acceleration factor: Standard 4; optional 16

7 comments:

  1. The device that MRI technicians work with looks like a donut and it has a tunnel inside. Now, once the patient is settled on the table, it moves into the tunnel. This is when the pictures are taken through the help of radio waves.http://techniciansalary.net/mri-tech-salary/. Click here

    ReplyDelete
  2. Direct Medical Imaging can provide medical Chillers for all of your imaging needs from 3 Ton to 15 Ton or more. Replace your old high maintenance cost Krauss or Filtrine chillers with low cost American made chillers.

    http://www.directmedicalimaging.com/

    ReplyDelete
  3. Thanks for sharing wonderful information with us. I would like to bookmark the page so i can come here again to read you, as you have done a great job
    MRI Scanning Services

    ReplyDelete
  4. very good information. Thanks for sharing useful information.
    Mri Scan

    ReplyDelete
  5. Nice Blog. It was an excellent blog. Thanks for sharing useful information. Aruna Diagnostics offering advanced level MRI scan services in Hyderabad. Please check below link. Thank You.
    MRI Scan Services

    ReplyDelete
  6. That was really Excellent blog because I have found there lot of valuable Information and I am very glad that you share this blog with us.
    MRI Scan In Hyderabad .

    ReplyDelete
  7. Wow excellent blog..That was really Excellent blog.Thanks for Sharing useful information.
    Radiology Services

    ReplyDelete